[2] OUTLINE OF AIR CONDITIONING SYSTEM
The machine is equipped with a thin large-capacity air
conditioner with outside air intake. Through the inside air
filter (9) as well as the outside air filter (4), the roof (8) and
reaches the air conditioner unit (1). The air is cooled and
dehumidified by this unit.
The resulting air is heated to a comfortable level. In
this way, the air being blown via the blow port can be kept
at comfortable temperature and humidity.
The 3 front blow ports (5) can be opened and closed
using the center knob of each port. The 4 side blow ports
(7) are opened and closed using the mode lever on the
control panel (6). With these ports open or closed, you
can feel your head cool and your feet warm.
Capacity (Cooling)
Capacity (Warming)
Kinds of refrigerant
(Charge amount)
Pressure sensor
(Low)
Pressure sensor
(High)
(1) Air Conditioner Unit
(2) Outer Roof
(3) Inside / Outside Air Selection
Damper
(4) Outside Air Filter
10-M36
Type 1
Type 2 and
(Swash
3 (Scroll
plate type
type
compressor)
compressor)
Factory
2.44 kW
3.3 kW
spec.
Factory
3.84 kW
4.34 kW
spec.
R134a
Factory
900 to 1000 g
spec.
1.98 to 2.21 lbs
0.196 MPa
Factory
2
2.0 kgf/cm
spec.
28.4 psi
3.14 MPa
Factory
2
32.0 kgf/cm
spec.
455 psi
(5) Front Blow Port
(6) Control Panel
(7) Side Blow Port
(8) Inner Roof
(9) Inside Air Filter