Kubota M6800S Workshop Manual page 491

Table of Contents

Advertisement

M6800 · M6800S · M8200 · M9000, WSM
2) Light Switch Continuity when Setting Switch at OFF Position
1. Disconnect the combination switch connector.
2. Set the light switch to the OFF position.
3. Measure the resistance with an ohmmeter across the B
to the T terminal, the B
terminal to the terminal 2.
4. If infinity is not indicated, the head light switch is faulty.
B
Resistance
B
(Switch at OFF position)
B
3) Light Switch Continuity when Setting Switch at HIGH-BEAM
Position
1. Measure the resistance with an ohmmeter across the B
to the T terminal and the B
2. If 0 ohm is not indicated, the head light switch is faulty.
B
Resistance (Switch at
HIGH-BEAM position)
B
4) Light Switch Continuity when Setting Switch at LOW-BEAM
Position
1. Measure the resistance with an ohmmeter across the B
to the T terminal and the B
2. If 0 ohm is not indicated, the head light switch is faulty.
B
Resistance (Switch at
LOW-BEAM position)
B
5) Turn Signal Light Switch when Setting Switch Knob at OFF
Position
1. Set the turn signal light switch to the OFF position.
2. Measure the resistance with an ohmmeter across the B
to the R terminal and the B
3. If infinity is not indicated, the turn signal light switch is faulty.
B
Resistance (Switch at
OFF position)
B
6) Turn Signal Light Switch when Setting Switch Knob at R
Position
1. Set the turn signal light switch to the R position.
2. Measure the resistance with an ohmmeter across the B
to the R terminal.
3. If 0 ohm is not indicated, the turn signal light switch is faulty.
Resistance (Switch at R
B
position)
9-S23
ELECTRICAL SYSTEM
terminal to the terminal 1 and the B
1
terminal – T terminal
1
terminal – 1 terminal
Infinity
1
terminal – 2 terminal
1
terminal to the terminal 1.
1
terminal – T terminal
1
0 Ω
terminal – 1 terminal
1
terminal to the terminal 2.
1
terminal – T terminal
1
0 Ω
terminal – 2 terminal
1
terminal to the L terminal.
2
terminal – R terminal
2
Infinity
terminal – L terminal
2
0 Ω
terminal – R terminal
2
KiSC issued 03, 2008 A
terminal
1
1
W1042584
terminal
1
W1043473
terminal
1
W1044119
terminal
2
W1044501
terminal
2
W1044955

Hide quick links: