Kubota M6800S Workshop Manual page 621

Table of Contents

Advertisement

M6800 · M6800S · M8200 · M9000, WSM
(C) Blower Motor
Blower Switch Test
1. Check the continuity through the switch with an ohmmeter.
2. If the continuity specified below are not indicated, the switch is
faulty.
Terminal
Position
OFF
Low
Blower
switch
Medium
High
(1) Blower Switch
Blower Motor Test
1. Remove the outer roof.
2. Turn the blower motor (1) by hand and check whether it turns
smoothly.
3. Disconnect the connector (2) of blower motor (1).
4. Connect a jumper lead from battery (3) positive terminal to
connector B terminal.
5. Connect a jumper lead from battery negative terminal to
connector E terminal momentarily.
6. If the blower motor does not run, check the motor.
(1) Blower Motor
(2) Blower Motor Connector
10-S34
4
3
2
A : Switch Side
(3) Battery (12 V)
CABIN
1
W1021517
W1024850
KiSC issued 03, 2008 A