Main unit
10

Main shaft sensor final assembly removal

1. Remove the screw 1, and then remove the main shaft sensor final
assembly.
2. Remove the screw 2, and then remove the main shaft sensor assembly
from the sensor holder.
11
Crank rod removal
1. Remove the 2 screws 1, and then remove the crank rod assembly from the
thread take-up cam.
Upper shaft unit
1
2
1
2 - 49