Test mode
9. [THREAD SET MOTOR TEST]
[MOVE ORIGIN POSITION]
[MOVE THREAD SET MOTOR] : Performs needle threading.
[MANUAL MOVE]
[CLOSE]
10. [SENSOR TEST]
The status of each sensor (including ENCODER A, ENCODER B, and TEST SW) is indicated using "H" or "L". A buzzer
goes off when the sensor status changes (excluding ENCODER A and ENCODER B).
Although the current angle of the main shaft is displayed at the last line, '?' is displayed until the status of the NEEDLE UP
sensor changes after power has been turned on.
[INITIALIZE] : Moves the angle of the main shaft to the initial adjustment position (approx. 350 deg.).
[CLOSE]
: Closes the <SENSOR TEST> screen.
11. [A/D TEST]
24V power supply voltage, 40V power supply voltage, frame sensor A/D value, and calculated results are displayed. The main
PCB mask program version and the check sum are also displayed.
* When turn on the power while pressing the [START/STOP] and [NEEDLE THREAD] button, you can directly go to <A/D
TEST> screen.
[LL]
: Saves the A/D value of the frame sensor at the LL frame attachment position.
[S]
: Saves the A/D value of the frame sensor at the S frame attachment position.
[CLOSE]
: Closes the <A/D TEST> screen.
[HOOP TYPE] : Open the frame sensor at the "OTHER2", "LL", "L", "M", "OTHER", "S", "CAP", "CYLINDER" and
"CAP". The number shown in parentheses is displayed the A/D value of the frame sensor. The lower step is
displayed only at the time of wearing the "CYLINDER" and "CAP2".
: Returns the thread motor to its origin.
: Moves the TH motor to stand by at the needle thread hook change position.
: Closes the <THREAD SET MOTOR TEST> screen.
4 - 9