Main unit
3

Thread take-up lever cover assembly (Step 2)

1. Attach the 6 needle thread presser plates 2 and the 6 springs
thread holder base 1, and then attach the 6 retaining rings E1.5.
2. Attach the NT lower thread cutter to the cutter cover 3, and then attach the
6 retaining rings CS5.
3. Attach the cutter cover assembly to the needle thread presser plates with
the screw 1. (6 locations)
4. Temporarily secure the thread holder base to the thread take-up lever cover
with the 2 screws 2.
5. Attach the rear cover 4 with the 4 screws (3 4, 2 each).
*Key point
• Lift the rear cover 4 and secure it.
1
2
3
4
S50
Thread tension unit
Screw, Pan
1.47 – 1.96 N-m
M3X4
Taptite, Bind B
0.39 – 0.78 N-m
M3X10
Screw, Bind
0.39 – 0.78 N-m
M2.6X3
5.5
3.4
Retaining rings E1.5
to the
S50
S50
3
Torque
Torque
Torque
SPRING
3
XC5962***
2
1
Retaining rings CS5
1
2
4
4
4
3
3 - 13