Audi A8 2003 Workshop Manual page 135

Hide thumbs Also See for A8 2003:
Table of Contents

Advertisement

– Remove bolt -4- and detach coolant connection.
– Detach hoses -2- and -6-.
– Remove bolts -1-, -3- and -5- and detach connection for ex‐
haust gas recirculation.
– Detach coolant hose -arrow- in front of bulkhead.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
– Disconnect vacuum hose -1- from vacuum pump.
Caution
Take care not to damage the vacuum hose. The vacuum hose
must be renewed if it is damaged.
– Remove bolts -2- and -3- and take off vacuum pump.
Installing
Installation is performed in reverse sequence; note the following:
Note
Renew seals and O-rings.
Secure all hose connections with the correct type of hose clips
(same as original equipment) ⇒ Electronic parts catalogue .
– Set drive lugs of vacuum pump so they engage in slots in
camshaft when vacuum pump is installed -arrows-.
Audi A8 2003 ➤
Brake system - Edition 03.2013
11. Vacuum pumps for brake servo
129