Maintenance
item No.
Setting the white line correction
U091
Description
Sets the error detection threshold value for white line correction and displays the count result of abnormal pix-
els.
Purpose
To perform when replacing the CIS, DP driver PWB or CIS roller.
Method
1. Press the start key.
2. Press [EXECUTE].
3. Press the start key. Holding of white reference data is started.
4. The count result of abnormal pixels is displayed.
Display
Calculation(R)
Calculation(G)
Calculation(B)
Setting: Threshold value setting
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.
Display
Threshold(R)
Threshold(G)
Threshold(Com)
Abnorm Pixel
Threshold
MODE
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Y111960-2
Description
Description
Abnormal pixel count result for color R
Abnormal pixel count result for color G
Abnormal pixel count result for color B
Description
Displaying of abnormal pixel detection
threshold value for color R
Displaying of abnormal pixel detection
threshold value for color G
Setting of abnormal pixel detection thresh-
old value for color B
Abnormal pixel threshold value setting
Switching between white line correction
mode ON/OFF
Service Manual
Setting range
Initial setting
-
-
-
-
0 to 1023
-
0 to 8191
75
0: OFF
0
1: ON
2: Test mode
2KR/2KS
1-3-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 4200mf