2KR/2KS
Maintenance
Section
part/location
Optical
Laser scanner unit
section
Contact glass
Slit glass
Mirror 1
Mirror 2 and mirror 3
Lens
Reflector
Exposure lamp
Optical rail
Original size sensor
Maintenance
Section
part/location
Transfer/
Transfer roller unit
separation
sections
Maintenance
Section
part/location
Developing
Developing unit
section
2-4-4
Maintenance
Method
cycle
Check or
User call
clean
Clean
Every service
Clean
Every service
Clean
User call
Clean
User call
Clean
User call
Clean
User call
Check or
User call
replace
Grease
User call
Check or
User call
clean
Maintenance
Method
cycle
Replace
500K
Maintenance
Method
cycle
Replace
500K
Service Manual
Points and cautions
Clean the shield glass with a dry
cloth.
Clean with alcohol and then a dry
cloth.
Clean with a dry cloth or alcohol (do
not clean with a wet cloth).
Clean with alcohol and then a dry
cloth only if vertical black lines
appear on the copy image.
Clean with alcohol and then a dry
cloth only if vertical black lines
appear on the copy image.
Clean with a dry cloth only if vertical
black lines appear on the copy
image.
Clean with a dry cloth only if vertical
black lines appear on the copy
image.
Replace if an image problem
occurs.
Check noise and shifting and then
apply scanner rail grease EM-50L.
Clean the sensor emitter and sensor
receiver with alcohol or a dry cloth
only if there is a problem.
Points and cautions
Replace. (Check and replace when
user call occurs.)
Points and cautions
Replace. (Check and replace when
user call occurs.)
Page
P.1-5-22
P.1-5-12
Page
P.1-5-29
Page
P.1-5-28