Code
C3210
CIS lamp problem
When input value at the time of CIS illu-
mination does not exceed the threshold
value between 5 s.
C3300
Optical system (AGC) problem
After AGC, correct input is not obtained
at CCD.
C3310
CIS AGC problem
After AGC, correct input is not obtained
at CIS.
C3500
Communication error between scan-
ner and SHD
An error code is detected.
C3900
Backup memory read/write problem
(ISC PWB)
Read and write data does not match.
C3910
Backup memory data problem (ISC
PWB)
Data in the specified area of the backup
memory does not match the specified
values.
C4000
Polygon motor synchronization prob-
lem
The polygon motor does not reach the
stable speed within 20 s of the START
signal turning on.
Y111960-2
Contents
Causes
Check procedures/corrective measures
Poor contact in the
Check the connection of connector on the
connector termi-
ISM PWB and the connector on the DP
nals.
driver PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective DP driver
Replace the DP driver PWB and check for
PWB.
correct operation.
Defective DP
Replace the DP inverter PWB and check for
inverter PWB.
correct operation.
Defective CIS.
Replace the CIS and check for correct oper-
ation.
Poor contact in the
Check the connection of connector YC5 on
connector termi-
the ISM PWB and the connector on the
nals.
inverter PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective exposure
Replace the exposure lamp or inverter
lamp or inverter
PWB.
PWB.
Defective PWB.
Replace the ISM PWB, ISC PWB or CCD
PWB and check for correct operation.
Defective DP driver
Replace the DP driver PWB and check for
PWB.
correct operation.
CIS output prob-
Replace the CIS and check for correct oper-
lem.
ation.
Defective DP
Replace the DP inverter PWB and check for
inverter PWB.
correct operation.
Poor contact in the
Check the connection of connector YC2 on
connector termi-
the CCD PWB and the connector YC2 on
nals.
the ISC PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective PWB.
Replace the CCD PWB or ISC PWB and
check for correct operation.
Defective backup
Replace the ISC PWB or ISM PWB and
RAM or PWB.
check for correct operation.
Defective backup
Replace the ISC PWB or ISM PWB and
RAM or PWB.
check for correct operation.
Poor contact in the
Check the connection of connector YC3 on
connector termi-
the engine PWB and laser scanner unit, and
nals.
the continuity across the connector termi-
nals. Repair or replace if necessary.
Defective polygon
Replace the laser scanner unit.
motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation.
Service Manual