Olivetti d-Copia 5200MF Service Manual page 127

Hide thumbs Also See for d-Copia 5200MF:
Table of Contents

Advertisement

2KR/2KS
Maintenance
item No.
Setting the target
U425
Description
Enters the lab values that is indicated on the back of the chart (P/N: AVGR05131K) used for adjustment. Also
enters the measurement value of the chart (P/N: AVGR11211F) used for adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set.
Display
CCD
DP
CIS
Setting: [CCD]
1. Select the item to be set.
Display
N875
N475
N125
CYAN
MAGENTA
YELLOW
RED
GREEN
BLUE
ADJUST ORIGINAL
2. Select the item to be set.
Display
L
A
B
3. Enters the value that is indicated on the back of the chart using the +/- or numeric keys.
4. Press the start key. The value is set.
1-3-90
Description
Description
Entering the target values of the chart (P/N: AVGR05131K) used for
adjustment
Entering the measurement value of the chart (P/N: AVGR11211F)
used for adjustment
Execution is not required
Description
Setting the N875 patch for the original for adjustment
Setting the N475 patch for the original for adjustment
Setting the N125 patch for the original for adjustment
Setting the cyan patch for the original for adjustment
Setting the magenta patch for the original for adjustment
Setting the yellow patch for the original for adjustment
Setting the red patch for the original for adjustment
Setting the green patch for the original for adjustment
Setting the blue patch for the original for adjustment
Setting the main and auxiliary scanning directions
Description
Setting the L value
Setting the A value
Setting the B value
Service Manual
Setting range
0.0 to 100.0
-200.0 to 200.0
-200.0 to 200.0
Y111960-2