4. Remove the round terminals from the scan-
ner wire springs on scanner unit left side.
5. Remove the scanner wire.
Fitting the scanner wires
6. Move the mirror 2 frame as shown in the fig-
ure and insert two frame securing tools into
the positioning holes at the front and rear of
the machine center to fix the mirror 2 frame
in position.
Y111960-2
Scanner wire
spring
Frame securing tool
Mirror 2 frame
Service Manual
Round terminal
Round terminal
Scanner wire
spring
Figure 1-5-35
Frame securing tool
Figure 1-5-36
2KR/2KS
1-5-17