Olivetti d-Copia 5200MF Service Manual page 163

Hide thumbs Also See for d-Copia 5200MF:
Table of Contents

Advertisement

2KR/2KS
Section
Description
Eject
51
section
Misfeed in job separa-
tor eject section
Feedshift
52
section
Misfeed in feedshift
section
Duplex
60
section
Duplex paper convey-
ing section 1
61
Duplex paper convey-
ing section 2
DP
70
No original feed
71
An original jam in the
original feed section
72
An original jam in the
original conveying sec-
tion
1-4-6
Conditions
The job eject switch (JESW) does not turn on within speci-
fied time of the feedshift switch (FSSW) turning on.
The job eject switch (JESW) does not turn off within speci-
fied time of the feedshift switch (FSSW) turning off.
The job eject switch (JESW) does not turn off within speci-
fied time of the feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn on within speci-
fied time of the start of eject motor (EM) reverse rotation.
During paper switchback operation, the feedshift switch
(FSSW) does not turn off within specified time of the its
turning on.
The feedshift switch (FSSW) does not turn off within speci-
fied time of the registration switch (RSW) turning off.
The feedshift switch (FSSW) does not turn off within speci-
fied time of the registration clutch (RCL) turning on.
The duplex paper conveying switch (DUPPCSW) does not
turn on within specified time of the feedshift switch (FSSW)
turning on.
The duplex paper conveying switch (DUPPCSW) does not
turn off within specified time of the feedshift switch (FSSW)
turning off.
The feed switch 1 (FSW1) does not turn on within specified
time of the duplex paper conveying switch (DUPPCSW)
turning on.
The feed switch 1 (FSW1) does not turn off within specified
time of the duplex paper conveying switch (DUPPCSW)
turning off.
The original feed switch (OFSW) does not turn on within
specified time during the first sheet feeding (Retry 5 times).
The original feed switch (OFSW) does not turn on within
specified time during the second sheet feeding (Retry 5
times).
During original tray ascent, the tray upper limit switch
(TULSW) does not turn on within specified time.
The original registration switch (ORSW) does not turn on
within specified time of the original feed switch (OFSW)
turning on.
DP timing switch 1 (DPTSW1) turns off within the specified
time since the switch turns on.
Service Manual
Specified time
1587 ms
1587 ms
1587 ms
1196 ms
2313 ms
2243 ms
2243 ms
2196 ms
2196 ms
1543 ms
1543 ms
1159 ms
1159 ms
2 s
1013 ms
914 ms
Y111960-2