Power problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 5, "Parts listing, System x3750 M4 Types 8722 and 8733," on page 195 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
Symptom
The power-control button does
not work, and the reset button
does work (the server does not
start).
Note: The power-control button
will not function until
approximately 10 seconds after
the server has been connected
to ac power.
The server does not turn off
The server unexpectedly shuts
down, and the LEDs on the
operator information panel are
not lit.
184
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Action
1. Make sure that the server has power by checking the ac power LED and the dc
power LED on the power supply. If both of the ac power LED and the dc
power LED are lit, reseat the power supply. If one of the LED is off, then see
"Power-supply LEDs" on page 164.
2. If you just installed an optional device, remove it and restart the server. If the
server now starts, you might have installed more devices than the power
supply can support.
3. Check the IMM event log and resolve any errors related to the device.
4. Replace the operator information panel cable.
5. If the problem remains, attempt to use the force power on jumper (see Table 2
on page 28). If the server starts, replace the operator information panel.
1. Determine whether you are using an Advanced Configuration and Power
Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI
operating system, complete the following steps:
a. Press Ctrl+Alt+Delete.
b. Turn off the server by pressing the power-on button and holding it down
for 5 seconds.
c. Restart the server.
d. If the server fails POST and the power-on button does not work, disconnect
the ac power cord for 20 seconds; then, reconnect the ac power cord and
restart the server.
2. If the problem remains or if you are using an ACPI-aware operating system,
suspect the system board.
1. Check the IMM event log for errors and resolve any errors associated with the
device.
2. If the problem remains, see "Solving undetermined problems" on page 189.