80030006-2101ffff
Sensor [SensorElementName] has deasserted.
Explanation: Secure UEFI update completed Successfully.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
80030108-0a01ffff
Sensor [SensorElementName] has asserted.
Explanation: Power Supply load has reached maximum capacity.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response: PS Heavy Load : The system will throttle to lower the load. Information only; no action is required.
8003010e-2581ffff
Sensor [SensorElementName] has asserted.
Explanation: IMM has detected that the memory size has changed.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.