S.3030007 • S.3058004
S.3030007
[S.3030007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for any service bulletins or firmware updates that apply to this error.
2.
Update the primary UEFI image.
3.
Replace the system board.
S.3040007
[S.3040007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for any service bulletins or firmware updates that apply to this error.
2.
Update the primary UEFI image.
3.
Replace the system board.
S.3050007
[S.3050007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for any service bulletins or firmware updates that apply to this error.
2.
Update the primary UEFI image.
3.
Replace the system board.
S.3058004
[S.3058004] A Three Strike boot failure has occurred. The system has booted with default UEFI
settings.
Explanation: POST failure has occurred! System booted with default settings.
Severity: Error
User response: Complete the following steps:
1.
This event resets UEFI to the default settings for the next boot. If successful, you will be required to go through
the Setup utility. The original UEFI settings are still present.
2.
If you did not intentionally reboot the system, check the event log for any events related to the system and
resolve those issues.
3.
Undo any recent system changes (settings or devices added). If there were no recent system changes, remove all
options from the system. Then remove the CMOS battery for 30 seconds to clear the CMOS contents. Verify that
the system boots. Then, re-install options one at a time to locate the problem.
4.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
5.
Update the UEFI firmware.
6.
Replace the system board.