806f050c-2581ffff • 806f050d-0401ffff
806f050c-2581ffff
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation: IMM has detected that the Memory Logging Limit has been Reached.
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0144
SNMP Trap ID: 43
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
806f050d-0400ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation: The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0401ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation: The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drive that is indicated by a lit status LED.
490