If the node does not successfully power on or if this is not the first occurrence of this problem, (trained service
v
technician only) replace the system board.
80070204-2584ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a Power Supply Fan (PS Fan Fault) has transitioned to critical.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1. Check for Power Supply with PS fault in the event log
2. Replace the Power Supply that has the PS Fault
80070208-2584ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a Power Supply Sensor has transitioned to critical. (PS CSF Fault or PS Therm Fault)
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1. Check for Power Supply with PS fault in the IMM event log
2. Replace the Power Supply that has the PS Fault
8007020f-2582ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a "No I/O Resources" Sensor has transitioned to critical.
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
80070204-2584ffff • 8007020f-2582ffff