80070201-0303ffff • 80070202-0701ffff
80070201-0303ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 3 temperature Sensor has transitioned to critical.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070201-0304ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 4 temperature Sensor has transitioned to critical.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070202-0701ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: The Planar Fault sensor has detected a problem with the system board.
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 1
Automatically notify Support: No
User response: Complete the following steps:
1. Remove any recently installed components.
2.
Try to power on the node.
If the node successfully powers on, complete the following steps:
v
a.
Check the ServerProven website to make sure that recently installed components are compatible with the
compute node.
b.
Inspect the previously installed components for physical damage.