I.1800E
[I.1800E] A processor model mismatch has been detected for one or more processor packages.
Explanation: The processors have mismatched model numbers.
Severity: Info
User response: Complete the following steps:
1.
Verify that matching processors are installed in the correct population sequence, according to the product
documentation for the system. See the section entitled, "Installing the microprocessor and heat sink" for more
information.
2.
Check the IBM support site for service bulletins or firmware updates that apply to this processor error.
3.
Replace the processor. While replacing the processor, inspect the processor socket and replace the system board if
the processor socket is damaged.
4.
Replace the system board.
I.1800F
[I.1800F] A processor family mismatch has been detected for one or more processor packages.
Explanation: The processors have mismatched families.
Severity: Info
User response: Complete the following steps:
1.
Verify that matching processors are installed in the correct population sequence, according to the product
documentation for the system. See the section entitled, "Installing the microprocessor and heat sink" for more
information.
2.
Check the IBM support site for service bulletins or firmware updates that apply to this processor error.
3.
Replace the processor. While replacing the processor, inspect the processor socket and replace the system board if
the processor socket is damaged.
4.
Replace the system board.
I.18010
[I.18010] A processor stepping mismatch has been detected for one or more processor packages.
Explanation: The processors of the same model have mismatched Stepping IDs.
Severity: Info
User response:
1.
Verify that matching processors are installed in the correct population sequence, according to the product
documentation for the system. See the section entitled, "Installing the microprocessor and heat sink" for more
information.
2.
Check the IBM support site for service bulletins or firmware updates that apply to this processor error.
3.
Replace the processor. While replacing the processor, inspect the processor socket and replace the system board if
the processor socket is damaged.
4.
Replace the system board.