IBM System x3750 M4 Type 8722 Installation And Service Manual page 549

Hide thumbs Also See for System x3750 M4 Type 8722:
Table of Contents

Advertisement

806f0a13-2401ffff
A Fatal Bus Error has occurred on bus [SensorElementName].
Explanation: IMM has detected a Bus Fatal Error.
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
806f0b13-3101ffff
Bus [SensorElementName] is operating in a degraded state.
Explanation: IMM has detected that the DMI Bus is degraded.
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0246
SNMP Trap ID: 60
Automatically notify Support: No
User response: Complete the following steps:
1. AC cycle the machine
2. Remove CPU 1 and inspect the CPU socket for bent pins.
3. Swap CPU 1 and CPU 2. If the error goes away, replace the original CPU 1.
4. If the problem persists, System board may need to be replaced.(Trained service personnel only)
81010002-2801ffff
Numeric sensor [NumericSensorElementName] going low (lower non-critical) has deasserted.
Explanation: A previously low CMOS battery voltage has returned to above its specified threshold
Severity: Info
Alert Category: Warning - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0477
SNMP Trap ID: 13
Automatically notify Support: No
User response: Information only; no action is required.
806f0a13-2401ffff • 81010002-2801ffff
Appendix D. Integrated management module II (IMM2) error messages
533

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3750 m4 type 8733

Table of Contents