2.6.3

Process

Classific
Code
ation
400
Fuser
Fuser unit error status
counter
556
Image
Image quality closed-loop
control
control/Contrast voltage
557
Image
Image quality closed-loop
control
control/Laser power
573
Image
Abnormality detection
control
count (Y)
Display/0 clearing
574
Image
Abnormality detection
control
count (M)
Display/0 clearing
575
Image
Abnormality detection
control
count (C)
Display/0 clearing
576
Image
Abnormality detection
control
count (K)
Display/0 clearing
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Functi
<Accept
Items
on
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2 - 85
Default
RAM
Contents
able
value>
0
M
0: No error
<0-51>
7: C467
24: C446
31: C4D0
1
M
Sets whether or not
<0-1>
correcting the contrast
voltage in closed-loop
control.
0: Invalid
1: Valid
1
M
Sets whether or not
<0-1>
correcting the laser
power in closed-loop
control.
0: Invalid
1: Valid
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]