[ 4.5 ] Setting the communications parameters and interface port
When the BHT-4000 is initialized, the communications parameters and the interface
port to be used are set as listed in the default table below. Do not access unless
necessary.
Communications parameters
Transmission speed (Bit rate)
Character length
Parity
Stop bits
Protocol
Interface port
SET COM ENVIRONMENT
1:Optical
2:Connector
3:Default
19,200 bps
8 bits
None
1 bit
Serial number ON:
Horizontal parity ON:
RS/CS control OFF:
Optical interface port
Selecting "Com" on the SET SYSTEM menu
displays the screen shown at left.
1 Optical
: Shifts to the communica-
tions parameter menu
screen for the optical in-
terface. (The CU-4000 is
required.)
2 Connector : Shifts to the communica-
tions parameter menu
screen for the direct-con-
nect interface.
3 Default
: Shifts to the interface port
setting screen.
Select a desired item by using the numeri-
cal keys and then press ENT key to shift
to the selected setting screen.
To return to the SET SYSTEM menu, press
C key.