Connection Timing Adjustment Incoming DFU
When the Call Center calls out to the access point where Embedded RC
Gate-M is used, the ID tone (*#1#) is sent repeatedly. This SP sets the
162
amount of time to elapse for ID tone output.
[0 to 24/1/1 pause count]
1 pause count = 2 sec.

Access Point DFU

This is the dial-up telephone line number of the access point connected to
163
Embedded RC Gate-M. If a number is entered here that number is used. If no
number is entered here then the pre-set country setting is used.

Line Connecting DFU

This SP code should be set for the customer using Embedded RC Gate-M,
depending on the line usage (whether line is shared with a fax or not).
164
[0 to 1/0/1]
0: Line shared with facsimile
1: Line not shared with facsimile
Modem Serial No. DFU
173
This SP code displays the serial number of the Embedded RC Gate-M
(modem).
Retransmission Limit DFU
174
Use this SP to manually send a registration update request to Embedded RC
Gate-M.
FAX TX Priority DFU
This SP is used with SP5816-164 for users who are using a line shared with a
facsimile unit.
[0 to 1/0/1]
187
0: Disabled. Embedded RC Gate-M continues to operate if a fax transmission
starts on the same line.
1: Enabled. Fax transmissions have priority. Embedded RC Gate-M will shut
down when a fax transmission begins.
SM Appendix
2-143