4012
Scanner Erase Margin
These SP's define borders around the image area output by the scanner. Each
edge can be set independent of the others.
5 DF: LEdge
6 DF: TEdge
7 DF: Left
8 DF: Right
4013
Scanner Free Run
These SP's set up and start the scanner free run operation for testing.
1 Start
This SP uses the most recent settings for the original length and interval between
sheets to print virtual pages for a scanner free run.
[ON] Start
[OFF] Stop
2 Page Interval Setting
Sets the interval between virtual prints for the scanner free run.
[0 to 25/ 0.9 /0.1 s]
3 Original Length Setting
Sets the interval between multiple feeds for the DF free run.
[0.2 to 15 / 0.6 /0.1 m]
4101
Scanner Main Scan Magnification
Adjusts the side-to-side scan magnification.
[-0.9 to +0.9/0.0/0.1 %]
SM
[0 to 9 / 1.5 /0.1 mm]
[0 to 9 / 0.5 / 0.1 mm]
6-37
Main SP Modes
D093/D094