Personal Information Protect - Ricoh D093 Service Manual

Table of Contents

Advertisement

SP5-xxx Mode
201 DocSvr Timeout
This SP sets the length of time for session timeout. The default is 30 min. The
time can be reduced to shorten the time between memory leak detections.
[1 to 255 / 30 / 1 min.]
5887
SD Get Counter
After you touch [EXECUTE] this SP sends a text file to an SD card inserted in
SD card Slot 2. The file is stored in a folder created in the root directory of the
SD card called SD_COUNTER. The file is saved as a text file (*.txt) prefixed
with the number of the machine.
Insert the SD card in SD card Slot 1 (lower slot).
Select SP5887 then touch [EXECUTE].
Touch [EXECUTE] in the message when you are prompted.
5888

Personal Information Protect

Selects the protection level for logs.
[0 to 1 / 0 / 1}
0: No authentication, No protection for logs
1: No authentication, Protected logs (only an administrator can see the logs)
SDK Application Counter
The machine stores up to six registered names in the SDK application.
5893
This SP has been implemented for all machines using Engine 08S and
later.
This SP is not needed if there are no SDK applications loaded.
1 to 6
SDK1 to SDK-6
D093/D094
2-186
CTL
CTL
CTL
SM Appendix