Lph Joint Adjustment - Ricoh D093 Service Manual

Table of Contents

Advertisement

2952

LPH Joint Adjustment

Adjust these settings only after you replace the LPH. For more, refer to
"Replacement and Adjustment".
1 LPH1-2 Main Scan
Adjusts the LPH joint for main scan between LPH1 and LPH2.
[0 to 999/500/1]
2 LPH2-3 Main Scan
Adjusts the LPH joint for main scan between LPH2 and LPH3.
[0 to 999/500/1]
11 LPH1-2 Sub Scan
Adjusts sub scanning at LPH 1-2 for paper more than 420 mm wide.
[300 to 500/412/1]
12 LPH2-3 Sub Scan
Adjusts sub scanning at LPH 2-3 for paper more than 420 mm wide.
[2 to 100/16/1]
51 LPH1-2 Sub Scan: < 420mm
Adjusts sub scanning at LPH 1-2 for paper less than 420 mm wide. This value is
calculated automatically.
[-50 to +50/0/1]
52 LPH2-3 Sub Scan: < 420mm
Adjusts sub scanning at LPH 2-3 for paper less than 420 mm wide. This value is
calculated automatically.
[-50 to +50/0/1]
SM
6-31
Main SP Modes
D093/D094

Advertisement

Table of Contents
loading

This manual is also suitable for:

D094

Table of Contents