SP2-XXX (Drum)

[Charge DC Voltage] Charge Roller DC Voltage Adjustment
(Paper Type, Process Speed, Color)
2005
Paper Type –> Plain, Thick 1, Thick 2
Adjusts the DC component of the charge roller bias in the various print modes.
Charge bias (DC component) is automatically adjusted during process control;
therefore, adjusting these settings does not effect while process control mode
(SP3-041-1 Default: ON) is activated. When deactivating process control mode
with SP3-041-1, the values in these SP modes are used for printing.
001 Plain: Bk
002 Plain: M
003 Plain: C
004 Plain: Y
005 Thick 1: Bk
006 Thick 1: M
007 Thick 1: C
008 Thick 1: Y
009 Thick 2&FINE: Bk
010 Thick 2&FINE: M
011 Thick 2&FINE: C
012 Thick 2&FINE: Y
013 Correction Plain
014 Correction Thick 1
015 Correction Thick 2&FINE
D023/D025
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 1000 / 690 / 10 –V/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[–100 to 100 / -24 / 1 –V/step]
*ENG
[–100 to 100 / –2 / 1 –V/step]
*ENG
[–100 to 100 / 2 / 1 –V/step]