Main SP Tables-2
SP2-XXX (Drum)
[Magnification Adjustment]
2102
These values are the parameters for the automatic line position adjustment and are
adjusted at the factory. These SPs must be input only when a new laser unit is installed.
001 Main Mag.: High Speed: Bk
004 Main Mag.: High Speed: Ma
007 Main Mag.: High Speed: Cy
010 Main Mag.: High Speed: Ye
Color Main Mag.: High Speed:
028
Ma
Color Main Mag.: High Speed:
031
Cy
Color Main Mag.: High Speed:
034
Ye
[Erase Margin Adjustment] (Area, Paper Size)
2103
Adjusts the erase margin by deleting image data at the margins.
001 Lead Edge Width
002 Trail. Edge Width
003 Left
004 Right
005 Duplex Trail
006 Duplex Left Edge
007 Duplex Right Edge
*ENG
*ENG
[-1.000 to 1.000 / 0.000 / 0.001/step]
*ENG
*ENG
*ENG
*ENG
[-1.000 to 1.000 / 0.000 / 0.001/step]
*ENG
*ENG
[0.0 to 9.9 / 4.2 / 0.1mm/step]
*ENG
*ENG
[0.0 to 9.9 / 2.0 / 0.1mm/step]
*ENG
*ENG
*ENG
[0.0 to 9.9 / 0.0 / 0.1mm/step]
*ENG