No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: K
The PFGATE ON signal still asserts within 5 seconds after
231
D
processing the image in normal job or MUSIC for end position [K].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after
232
D
processing the image in normal job or MUSIC for start position [Y].
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: Y
The PFGATE ON signal still asserts within 5 seconds after
233
D
processing the image in normal job or MUSIC for end position [Y].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
SM Appendix
3-13
SC Tables
D023/D025