026 Job End Vb Coefficient
027 Job End Length
028 Job End Supply
[Blade damage prevention mode]
Adjusts the threshold temperature for preventing the cleaning blade at the
3517
drum unit from being damaged. If the temperature is above this value, the
drum reverses briefly at the end of the job to prevent the blade from flipping
over.
Execution Temp.
001
Threshold
SM Appendix
*ENG
[0 to 100 / 40 / 1%/step]
*ENG
[0 to 56 / 12 / 1mm/step]
[0 to 1 / 0.45 / 0.001
*ENG
mg/cm
*ENG
[0 to 50/ 40 / 1°C/step]
8-179
System Service Mode
2
/step]