1115
[Stand-by Idling]
Interval
001
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
Idling Time
002
Specifies the length of each idling operation during stand-by mode.
Idling Speed
003
1116
[Ends Temp. Correction]
Center Temp. 1: 226–
010 Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
Ends Temp. 1: 226–
011 Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
Center Temp. 2: 226–
012 Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
SM Appendix
*ENG
[1 to 240 / 60 / 1 min/step]
*ENG
[1 to 60 / 2 / 0.1 sec/step]
*ENG
[0 to 1 / 0 / 1 mm/sec/step]
ENG
[-10 / 10 / 5 / 1 deg/step]
ENG
[-10 to 10 / 5 / 1 deg/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
8-15