[Forced Ready Setting]
1108
Japan use only
007 Time
1109
[Fusing Nip Band Check]
001
Execute
Pre-Idling Time
002
Specifies the fusing rotation time before executing SP1109-001.
Stop Time
003
Specifies the time for measuring the nip.
1112
[Environmental Correction: Fusing]
Temp.: Threshold: Low
001
Specifies the threshold temperature for low temperature condition.
Temp.: Threshold: High
002
Specifies the threshold temperature for high temperature condition.
Low Temp. Correction
003 Specifies the temperature correction for the heating roller. When the low
temperature condition (specified with SP1112-001) is detected, the value of
this SP is added to the heating roller temperature.
SM Appendix
*ENG
[22 to 60 / 22 / 0.1 sec/step]
[0 or 1 / 0 / 1]
Executes the nip band measurement
between fusing belt and pressure roller.
-
If the nip band width is not 8 mm, and
fusing is not good, replace the pressure
roller or install a new fusing unit.
*ENG
[0 to 120 / 0 / 1 sec/step]
* ENG
[5 to 30 / 10 / 1 sec/step]
*ENG
[10 to 23 / 17 / 1 deg/step]
*ENG
[24 to 40 / 30 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]