Control Time 2: 226–
Specifies the start time of the temperature correction that is set with
019
SP1116-012 and -013.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 3: –226
Specifies the start time of the temperature correction that is set with
020
SP1116-014 and -015.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 4: –226
Specifies the start time of the temperature correction that is set with SP1116-016
021
and -017.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
022 M-Thick 1: Center Temp >=226
023 M-Thick 1: Ends Temp. >=226
024 M-Thick 2: Center Temp >=226
025 M-Thick 2: Ends Temp. >=226
026 M-Thick 3: Center Temp >=226
027 M-Thick 3: Ends Temp. >=226
028 M-Thick 4: Center Temp >=226
029 M-Thick 4: Ends Temp. >=226
030 Other1: Center Temp >=226
031 Other1: End Temp >=226