Pressure Ready Temp
007 Sets the heating roller offset temperature at the end of the heating roller. This
value is one of the thresholds to determine if the machine is at the heating roller
target temperature during warm-up.
010 Stand-By: Center
011 Stand-By: End
Stand-By: Pressure
012 Sets the pressure roller offset temperature. This value is one of the thresholds
to determine if the machine is at the heating roller target temperature during
warm-up.
013 Panel Off Mode: Center
014 Panel Off Mode: Ends
015 Panel Off Mode: Pressure
016 Low Power: Center
017 Low Power: Ends
018 Low Power: Pressure
019 Off Mode: Center
020 Off Mode: Ends
021 Off Mode: Pressure
SM Appendix
*ENG
[0 to 150 / 20 / 1 deg/step]
* ENG
[140 to 170 / 155 / 1 deg/step]
* ENG
* ENG
[105 to 135 / 120 / 1 deg/step]
* ENG
[100 to 150 / 130 / 1 deg /step]
* ENG
[100 to 150 / 130 / 1 deg /step]
*ENG
[105 to 135 / 120 / 1 deg /step]
*ENG
[30 to 100 / 40 / 1 deg /step]
*ENG
*ENG
[30 to 135 / 80 / 1 deg /step]
*ENG
[0 to 180 / 0 / 1 deg /step]
*ENG
*ENG
[0 to 170 / 0 / 1 deg /step]
8-7
System Service Mode
D023/D025