Ricoh D025 Service Manual page 545

Table of Contents

Advertisement

Rev. 10/06/2010
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Operation panel management records exceeded
An error occurred because the number of records exceeded the limit for
images managed in the service layer of the firmware. This can occur if
CTL
994
there if there are too many application screens open on the operation
C
panel.
No action required because this SC does not interfere with
operation of the machine.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
995
D
CPM setting error
Defective BICU
NVRAM Replacement error
-001
1.
Install the previous NVRAM.
2.
Input the serial number with SP5811-004, and turn the main power
switch off/on.
Defective NVRAM
Defective controller
-002
1.
Update the controller firmware.
2.
Install a new NVRAM, and turn off and on the main power switch
after SC995-002 has occurred.
Incorrect type controller installed
Defective controller
-003
1.
Replace the controller with the correct type.
Incorrect model controller installed.
-004
1.
Replace the controller with the correct model.
SM Appendix
3-93
SC Tables
D023/D025

Advertisement

Table of Contents
loading

This manual is also suitable for:

D023