Ricoh D025 Service Manual page 463

Table of Contents

Advertisement

No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal goes HIGH (inactive) while the laser diode is
firing.
Disconnected or defective harness to polygon motor driver board
204
D
Defective polygon motor
Defective polygon motor driver board
1.
Check or replace the harness.
2.
Replace the polygon motor.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
210
C
Laser synchronizing detection error: end position [K]
211
C
Laser synchronizing detection error: end position [Y]
212
C
Laser synchronizing detection error: end position [M]
213
C
Laser synchronizing detection error: end position [C]
The laser synchronizing detection signal for the end position of LDB [K],
[Y], [M], [C] is not detected for one second after the LDB unit turned on
when detecting the main scan magnification.
Disconnected or defective harness to synchronizing detector for
end position
-
-
Defective synchronizing detector board
Defective LD board or driver
Defective BICU
1.
Replace the harness of the LD board.
2.
Replace the laser optics housing unit.
3.
Replace the BICU.
SM Appendix
3-11
SC Tables
D023/D025

Advertisement

Table of Contents
loading

This manual is also suitable for:

D023

Table of Contents