System Service Mode
[Image Quality Adj.: Interval]
3512
Adjusts the timing for execution of process control and line position
adjustment.
001 During Job
002 During Stand-by
[PCU Motor Stop Time: Bk]
3513
Displays the last time that the PCU motors stopped.
These are used for process control execution timing.
001 Year
002 Month
003 Date
004 Hour
005 Minute
[Environmental Display: Job End]
3514
Displays the environmental conditions for the last job.
These are used for process control execution timing.
001 Temperature
002 Relative Humidity
003 Absolute Humidity
D023/D025
*ENG
[0 to 100 / 30 / 1 page/step]
*ENG
[0 to 100 / 10 / 1 minute/step]
*ENG
[0 to 99 / 0 / 1/step]
*ENG
[1 to 12 / 1 / 1/step]
*ENG
[1 to 31 / 1 / 1/step]
*ENG
[0 to 23 / 0 / 1/step]
*ENG
[0 to 59 / 0 / 1/step]
*ENG
[-1280 to 1270 / 0 / 0.1°C/step]
*ENG
[0 to 1000 / - / 0.1%RH/step]
*ENG
[0 to 1000 / - / 0.1 g/cm
8-176
3
/step]