System Service Mode
5501
[PM Alarm]
001 PM Alarm Level
002 Original Count Alarm
5413
[Lockout Setting]
001 Lockout On/Off
002 Lockout Threshold
003 Cancellation On/Off
D023/D025
*CTL -
[0 to 9999 / 0 / 1 /step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1 to 9999)
x 1000 ≥ PM counter
[0 or 1 / 1 / – ]
0: No alarm sounds
1: Alarm sounds after the number of originals
passing through the ARDF ≥ 10,000
Switches on/off the lock on the local
address book account.
*CTL
[0 to 1/0/1]
0: Off, 1: On
Sets a limit on the frequency of lockouts for
*CTL
account lockouts.
[1 to 10/5/1]
Determines whether the system waits the
prescribed time for input of a correct user
ID and password after an account lockout
has occurred.
*CTL
[0 to 1/0/1]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if
correct user ID and password are entered.