FrameMaker Ver.5.5E(PC) Di350 TROUBLESHOOTING
98.12.09

(12) Rough Image

Section Step
Engine
1
Is the Image Transfer Roller
dirty?
2
Is the image transfer current ter-
minal intact?
IR
1
Do the connections from CCD to
HGB remain intact?
2
Do the connections from HGB to
UN2 remain intact?

(13) Periodically Uneven Image

Section Step
Engine
1
Is the Developing Unit drive gear
cracked or dirty with foreign mat-
ter?
2
Is the PC Drum drive gear
cracked or dirty with foreign mat-
ter?
3
Is the Synchronizing Roller drive
gear cracked or dirty with foreign
matter?
4
Is the Fusing Unit drive gear
cracked or dirty with foreign mat-
ter?
5
Is the PH Assy secured properly? YES
IR
1
Is the Scanner Motor drive gear
cracked or dirty with foreign mat-
ter?
2
Is the Scanner Motor secured
properly?
3
Is the Scanner secured properly?
4
Are the Scanner Drive Cables
wound properly?
5
Are the Scanner rails damaged
or dirty with foreign matter?
6
Do the connections from CCD to
HGB remain intact?
7
Do the connections from HGB to
UN2 remain intact?
Check Item
Check Item
T-52
Result
YES
Clean or change.
YES
Change HV1, I/C, PH Unit, or
PWB-A, in that order.
NO
Check and change as neces-
sary.
NO
Reconnect.
YES
Change CCD, HGB, or UN2, in
that order.
NO
Reconnect.
Result
YES
Clean or change.
YES
Clean or change.
YES
Clean or change.
YES
Clean or change.
Change the I/C or PWB-A.
NO
Secure properly.
YES
Clean or change.
NO
Secure properly.
NO
Secure properly.
NO
Wind the cables properly.
YES
Clean or change.
NO
Reconnect.
YES
Change CCD, HGB, or UN2, in
that order.
NO
Reconnect.