FrameMaker Ver.5.5E(PC) Di350 GENERAL, MECHANICAL/ELECTRICAL
98.12.18
1171SBM1402A

14-2. MP Cassette-in-Position Detection

• When the MP Cassette is slid into the copier, the light blocking plate located in the rear of
the cassette blocks the Cassette Set Sensor and the copier determines that the MP Cas-
sette has been slid into position.
Cassette Set Sensor (PC6)
Electrical Component
PC6
Light Blocking Plate
Control Signal
PJ13A-5B
M-34
1167M052AB
Unblocked
H
Blocked
L