FrameMaker Ver.5.5(PC) Di350 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.11.25

(2) System Input

• This function allows the Tech. Rep. to change the fixed zoom ratios, set the paper size,
define the marketing area, configure for the Key Counter, and input the telephone num-
ber.
<Setting Procedure>
1. Touch [System Input] to open the System Input menu screen.
2. Touch the desired subfunction key.
Touch Panel
Display
Paper Size Input
Change Fixed
Zoom
Machine Configu-
ration
Technical Memo
Permit Imaging
Cartridge
Original Size
Detecting Option
Tech. Rep. Mode
Set the size of the paper used in each paper source.
This function cannot be used for the LCC as its paper is set with its
internal DIP switch.
<Procedure>
1. Touch the key of the paper source for which the paper size setting
is to be changed to show the Paper Size Input screen.
2. Touch the desired paper size key.
If the 10-key Pad has been selected, enter the FD and CD size of
the paper from the 10-Key Pad.
3. Touch [END] to validate the paper size setting.
Change a fixed zoom ratio to a desired value in the range between
×0.250 and ×4.000.
<Procedure>
1. Touch the key of the fixed zoom ratio to be changed.
2. Press the Clear key to clear the setting and enter the new ratio
from the 10-Key Pad.
3. Touch [Input] to validate the new setting.
Displays the machine configuration status.
Enter the serial number and other data.
Select whether to permit the use of an illegal Imaging Cartridge
installed. The use is enabled when [Enter] is touched after "Yes" has
been selected.
It is not possible to disable the use of an Imaging Cartridge once
permitted.
Yes
Set whether the optional Original Size Detecting Sensor is available
or not.
ON
System Input
Operation
S-22
No
OFF