FrameMaker Ver.5.5(PC) Di350 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.11.25
3-3.

UN1 (Control Panel)

Symbol
SW37 Warm Restart Switch
3-4.

PWB-L (PPM Switching Board)

Symbol
S1
Low-Speed Mode
Selecting Switch
Name
• Used to enter the initial mode.
• Used to restart the copier after a breakdown.
Name
Used to make longer the paper-to-paper intervals as
a means of preventing the problem in which sheets of
paper are fed out untidily when large size paper left to
stand under high humidity condition is being used.
Keep this switch in the H position, as it is only for
special users.
S-6
1167S018AA
1167S018AA
Description
1167S026AB
1167S026AB
Description