FrameMaker Ver.5.5E(PC) Di350 TROUBLESHOOTING
98.12.09
<Manual Bypass Take-Up Misfeed Troubleshooting Procedure>
Symptom
Paper is not taken
up at all.
Paper is at a stop
near the Synchro-
nizing Rollers.
Step
Check Item
1
Does the paper being used
meet the product specifica-
tions?
2
Is the paper curled, wavy, or
damp?
3
Is the Manual Feed Paper
Take-Up Roller or Roll
deformed, worn, or dirty with
paper dust?
4
Is PC8 fully operational?
Check the input data using I/O
Check.
5
Check CL3 for operation.
Does the voltage across
CN14-2 and GND change from
DC24V to DC0V when the
misfeed condition is reset?
1
Is PC2 fully operational?
Check the input data using I/O
Check.
Result
NO
YES Change the paper. Instruct the
YES Clean or change the Manual
NO
YES Check various parts for possi-
NO
YES Check various parts for possi-
NO
T-17
Action
Instruct the user to use the
paper that meets product
specifications.
user on the storage of paper.
Feed Paper Take-Up Roller or
Roll.
Check the PC8 actuator for
operation and, if it is intact,
change PC8.
ble overload and, if they are
okay, change CL3.
Change PWB-A.
ble overload and, if they are
okay, change PWB-A.
Check the PC2 actuator for
operation and, if it is intact,
change PC2.