(4) Edge Erase

1. Leading
Requirement
A
NOTE
This adjustment must be made when the PH Unit has been replaced and after Registration
(CD/FD) (Printer) has been made.
Adjustment Procedure
1. Call the Tech. Rep. mode to the screen.
2. Touch [Tech. Rep. Choice], then [Printer].
3. Touch [Edge Erase] and then [Leading] to enter the Leading Edge Erase adjustment
mode.
4. Press the Clear key to clear the current setting.
5. Enter the new setting value from the 10-Key Pad.
Setting Instructions
To make the edge erase width smaller, decrease the setting value.
To make the edge erase width greater, increase the setting value.
Setting Value
6. Touch the [END] key to validate the setting value.
Caution
Be sure to touch the END key before returning to normal operation mode. If the Panel
Reset Key is used, the previous setting remains valid.
Adjust so that the erase width on the leading edge falls
within the range of 0 to 5 mm.
Edge Erase/Leading
1171D003AA
1171D031CA
D-35
Adjust Mode
Use to clear setting value.
Use to enter setting value.
Setting Range
0 to 5
1167D069AA