FrameMaker Ver.5.5E(PC) Di350 DIS/REASSEMBLY, ADJUSTMENT
98.12.09
3-6.

OTHER ADJUSTMENTS

• Focus-Positioning of the Scanner and 2nd/3rd Mirrors Carriage
NOTE
Make this adjustment after any of the following procedures has been performed:
• After the Scanner Drive Cable has been replaced.
• When the Scanner Fixing Bracket has been removed from the Scanner Drive Cable.
• When the Scanner Drive Cable comes unwound.
Requirement
With the Scanner fixed to the Scanner Drive Cables, there should be no gap between the
Scanner/Mirrors Carriage Positioning Jig and the Scanner and also between the Scanner/
Mirrors Carriage Positioning Jig and the 2nd/3rd Mirrors Carriage.
Adjustment Procedure
Scanner/Mirrors Carriage Positioning Jig
Scanner
1. Remove the Exposure Lamp. (For details, see
steps 1 through 7, (8) Removal of the Scanner, 2-4
OPTICAL SECTION.)
2. Temporarily loosen the set screws of the cable
holding plate of the Scanner Drive Cable.
1167D113AA
3. Fit the Scanner/Mirrors Carriage Positioning Jigs in
the space between the Scanner and 2nd/3rd Mir-
rors Carriage.
1167D114AA
4. Press the Scanner up against the jig and 2nd/3rd
Mirrors Carriage and, at the same time, tighten the
set screws of the cable holding plate.
2nd/3rd
Mirrors
Carriage
1167D115AC
D-51