Cleaning Of The Pre-Image Transfer Guide Plate; Replacement Of The Ozone Filter - Minolta Di350 Service Manual

Hide thumbs Also See for Di350:
Table of Contents

Advertisement

FrameMaker Ver.5.5E(PC) Di350 DIS/REASSEMBLY, ADJUSTMENT
98.12.09

(3) Cleaning of the Pre-Image Transfer Guide Plate

(4) Replacement of the Ozone Filter

2. Using a soft cloth dampened with alcohol, wipe the
Comb Electrode.
NOTES
• Make sure the alcohol does not touch the surface of
the Image Transfer Roller.
• When wiping the Comb Electrode, make sure the
cloth is not caught by the ends of the combs.
1167D009AA
1. Open the Side Cover.
1171D021AA
2. Using a soft cloth dampened with alcohol, wipe the
Pre-Image Transfer Guide Plate.
NOTE
Make sure the alcohol does not touch the surface of
the Image Transfer Roller.
1167D010AA
1. Remove the Rear Lower Cover.
2. Pull out the Ozone Filter and replace it.
1171D022AC
D-24