FrameMaker Ver.5.5(PC) Di350 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.11.25
Touch Panel
Display
Image Density
ATDC Sensor
Gain
VG Adjust
<ADFR>
Touch Panel
Display
Original Stop
Position
Registration Loop
Tech. Rep. Mode
Setting (The default is
Set the image density for the printer.
The value set for this function becomes the central value of "Print
Exposure" of User's Choice.
-2..............................
Lighter
Current: Shows the current ATDC control voltage.
Set: Set the ATDC control voltage.
If the "Set" value is to be changed, be sure to record the "Current"
value.
The ATDC Sensor Gain value can be converted to a voltage value
using the following equation.
ATDC Sensor Gain = 5.1 × 2.2 × [setting value] ÷ 256 (V)
123 .........................
T/C Greater
Set VG when a fog or void occurs in the image.
-2..............................
Lighter
Setting (The default is
Set the document stop position in each of the ADFR modes.
1-Sided Set
2-Sided Set
Single Feed Set
The minimum setting value is -6 only for 2-Sided Set.
Set the loop length to be formed in the original before the Registration
Roller of ADFR.
-5mm........................
Smaller
Tech. Rep. Choice
0
........................... +4
...................... 186
155
........................... +2
0
-7..............................
Original Width
Scale end
0
..................... +5mm
S-20
).
Highlighted
Darker
T/C Smaller
Darker
Highlighted
).
.......................... +7
0
Original Glass
end
Greater