3-5. OTHER ADJUSTMENTS

(1) Adjustment of the Scanner/Mirrors Carriage Position

Requirement
With the Scanner positioned correctly with reference to the upper copier frame, there should be
no gap between the Scanner/Mirrors Carriage and the Scanner/Mirrors Carriage Positioning Jig.
1. Remove the Original Cover, Original Scales, and
Original Glass.
2. Temporarily tighten the screw on the Scanner Drive
Cable Holding Bracket.
3. Align the rectangular hole in the upper copier frame
with the U-groove in the Scanner, then insert the
Scanner Positioning Jig into the hole.
4. Install the Scanner/Mirrors Carriage Positioning Jig
between the Scanner and Mirrors Carriage.
5. Loosen the screw that has been temporarily tightened
in step 2. Turn the helical gear of the Scan Pulley to
press the Mirrors Carriage up against the
Scanner/Mirrors Carriage Positioning Jig and the
Scanner.
6. Tighten the screw on the Scanner Drive Cable Holding
Bracket to the specified torque.
D-64