Set Date - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB CLI (Command Line Interface) Operations
When this command is issued without parameter, the command assumes that the MMB connected to the
CLI is specified as the active MMB.
Remarks
This command can be executed by connecting to Standby MMB.
It is different from Switch Over function of MMB Web-UI.
Privilege: Administrator, CE
(1)
Input format
set active_mmb {0 | 1} {quiet}
(2)
Option
0: MMB#0 is specified
1: MMB#1 is specified
quiet: Command is executed without interacting with the user.
(3)
Usage example
None
(4)
Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN).
The specified MMB#x is NOT present.
The specified MMB#x is disabled.
The specified parameter is invalid.
Are you sure to continue set active mmb? [y/n]:
set active_mmb failed.

2.2.13 set date

Set the date and time.
The set format is as following.
MM : Month (01~12)
DD : Date (1~28|29|30|31)
hh : Time(00~23)
mm : Minutes(00~59)
CC : First two digits of the year (option)
YY : Last two digits of the year (option)
SS: Seconds (option)
Privilege: Administrator
(1)
Input format
set date MMDDhhmm{{CC}YY}{, SS}
(2)
Option
None
(3)
Usage example
None
(4)
Message

Advertisement